Service Pack 2010.04
General / Environment
􀁺 Increased number of possible CPU threads to 32. New Feature!
􀁺 Avoid automatic update of result templates when opening projects to ensure backward compatibility.
􀁺 Windows Explorer extension which displays project information can now handle very large CST files.
Modeler / Structure Visualization / Imports
􀁺 Adjusted procedure of face port creation to deal with very small ports.
􀁺 Fixed special issue when bending on a planar face where the sheet already lies on.
􀁺 Adjusted behavior of background material creation during project open in case of FPBA and a PCB import.
􀁺 Repaired an issue when editing certain rotate objects.
EDA Imports
􀁺 Added automatic port creation to PCB import. New Feature!
􀁺 Repaired creation of oblong pad shape for antipads in Cadence import.
􀁺 Corrected pad connectivity in Cadence import.
􀁺 Missing or corrupted board outline in PADS and Cadence import is now recreated automatically.
􀁺 Corrected visualization of die stack layers for Cadence SiP import in PCB import dialog box.
􀁺 Added healing function to repair touching circular antipads. New Feature!
􀁺 Added straight line geometry option as fall-back solution for etch creation during PCB import.
Distributed Computing (DC)
􀁺 Enabled GPU computing with DC for Windows Vista and higher operating systems. New Feature!
􀁺 Improved file transfer speed for Windows operating systems.
􀁺 Assured integrity of jobs in DC Main controller.
􀁺 Number of frequency samples in CST DS cache were not updated correctly when using distributed frequency samples.
􀁺 CST MWS parameterized block in CST DS did not start a DC calculation when used on a canvas with a schematic block.
􀁺 Repaired calculation of multiple goals if optimized with DC.
Hexahedral (Hex) Mesh
􀁺 Connectivity information is now calculated correctly if two lumped elements touch each other at terminal locations.
CST MICROWAVE STUDIO - Transient Solver
􀁺 Increased time domain solver performance for new Intel CPUs (Westmere processor) on Windows.
􀁺 Repaired issue in the import of MPI machine files.
􀁺 Corrected handling of dispersive materials for post processing and coupled simulations.
􀁺 Fixed error in PML setup for time domain solver when magnetic symmetry is used.
Changes in the Service Packs Seite 1 von 12
file://E:\CST STUDIO SUITE 2010\Online Help\general\spotlight\changes_in_the_service_pack.htm 14.06.2010
􀁺 Repaired setup of dispersive materials for GPU computing.
􀁺 Fixed error in parallelization of lossy metal.
􀁺 Improved setup of a super imposed plane wave.
􀁺 Repaired the disabled AR-filter start button for simultaneous or plane wave excitations.
CST MICROWAVE STUDIO - Frequency Domain (FD) Solvers
􀁺 Improved stability of the tetrahedral FD solver when reading mesh files with three-fold periodicity.
􀁺 When distributing only two frequency samples, the frequency sweep sometimes stopped after only three samples. One of the samples
was calculated twice.
􀁺 Distributed computing 1D results were missing in the ASCII and SQL storage mode when the adaptive mesh refinement of the
tetrahedral FD solver was turned off.
􀁺 Field monitors added after the end of frequency distributed computing were sometimes not added to the result tree.
􀁺 Loss monitors are now also written for tensor formula materials.
􀁺 For unit cells with negative sine of theta, Floquet mode excitation phase and Floquet farfield calculation were inconsistent.
􀁺 Periodic problems with solid lossy metal touching the lower periodic or unit cell boundary plane sometimes caused an error message
referring to an Unknown dof type.
CST MICROWAVE STUDIO - Integral Equation Solver
􀁺 Improved port mode calculation in MPI mode.
CST MICROWAVE STUDIO - Asymptotic Solver
􀁺 Added ability to define multiple polarizations for incident plane waves. New Feature!
CST PARTICLE STUDIO Solvers
􀁺 Phase space plots now are correctly initialized to have square-markers of size 2 by default.
􀁺 Ensure correct data order in result files for the PIC collision detection.
􀁺 Added missing collision info file for the GUN solver file in mesh adaptation mode.
CST MPHYSICS Solvers
􀁺 Improved warning message for thermally non conductive background material.
􀁺 Fixed problem with loss import of power densities in thermal solver.
􀁺 Fixed problem with symmetries for transient thermal monitors.
CST PCB STUDIO
􀁺 Fixed issue concerning missing component pins when importing LDB files with original data from ODB++.
􀁺 Repaired problems with reading negative rotation angles.
CST MICROSTRIPES
􀁺 Corrected position of discrete ports and lumped elements when imported from CST MWS.
CST DESIGN STUDIO
􀁺 Improved S-parameter calculation for combine results.
􀁺 Repaired issue when switching results of S-parameter watches to Smith chart view.
􀁺 Improved handling of CST MWS blocks when using combine results.
􀁺 Change probe direction was not recognized by template based post processing.
􀁺 Fixed problem with local voltage and current units in transient task.
􀁺 Repaired result file deletion on delete results for linked results.
􀁺 Fixed restoring of missing files from internal cache in CST DS sub blocks.
􀁺 Repaired issue with setting units by VBA command,
Post Processing / Fields
Changes in the Service Packs Seite 2 von 12
file://E:\CST STUDIO SUITE 2010\Online Help\general\spotlight\changes_in_the_service_pack.htm 14.06.2010
􀁺 Added linear scaling option for farfields. New Feature!
􀁺 Scaling of the farfield ASCII export is now independent from the selected component.
􀁺 Repaired issue with non ASCII names of components when using the new 3D field visualization engine.
Result Templates / VBA / Macros / External Data Access
􀁺 Added VBA command Port.GetFacePortArea to determine the area of a discrete face port. New Feature!
􀁺 New VBA commands XAutoTick, YAutoTick, XLogarithmic, YLogarithmic, UseCurveSmoothing and ShowReferenceCircle" added to
the Plot1D object. New Feature!
􀁺 Repaired VBA command GetFieldVector for 2D planes.
􀁺 The type is now correctly copied in the method Result3D.CopyFrom.
􀁺 Added VBA command to deliver surface losses from a QFactor calculation. New Feature!
在你的更新管理器里先把SP版本恢复到原始版本,然后导入新的SP,安装一遍,再次破解一次,ok。我老早在2009的时候就是出现啥SP就装SP,不然为了一个SP删除重新安装一次,神经啊。嘿嘿。